P318

An American-made triplex plunger positive displacement pump with reciprocating plungers for direct or belt drive applications.

Features:
Aluminum crankcase with sight glass and vented dipstick; forged, through-hardened, ground and polished crankshaft; bronze connecting rods; hardened stainless steel plunger bases; solid ceramic plungers; nitrile seals (with fabric reinforcing); stainless steel valves and forged brass manifold.

Options:
Gearbox and bell housings (to connect to gasoline, diesel, electric or hydraulic drive), couplers (aluminum or Delrin), unloader/regulator, fixed or adjustable chemical injector, thermal relief valve and pulsator valve.

  • P318 Exploded View
  • P318 Parts List
  • P318 Torque Specifications

Sorry, there are no accessories associated with this product.

  • Giant Industries Limited Warranty
  • P318 Installation Instructions
  • P318 Repair Instructions
  • Troubleshooting Guide

SPECIFICATIONS

U.S. Metric
1450 RPM
Max Flow 4.8 GPM 18.2 L/min
Nominal Pressure 2000 PSI 140 bar
Power Required (Nominal) 6.6 hp 4.9 kW
1750 RPM
Max Flow 5.8 GPM 22.0 L/min
Nominal Pressure 1000 PSI 70 bar
Power Required (Nominal) 4.0 hp 3.0 kW
Common Specifications
Inlet Pressure 145 PSI 10 bar
Maximum Temperature 160 °F 70 °C
Plunger Diameter 0.79″ 20 mm
Stroke 0.56″ 14.1 mm
Crankshaft Diameter 24 mm
Shaft Rotation Top of Pulley Towards Manifold
Shaft Mounting Either Side
Inlet Ports (2) 1/2″ BSP
Discharge Ports (2) 3/8″ BSP
Crankcase Oil Capacity (short) 14.2 fl. oz. 0.42 L
Crankcase Oil Capacity (extended) 17.0 fl. oz. 0.5 L
Weight 16 lbs. 7.3 kg
Key Component Material
Manifold Forged Brass
Plungers Solid Ceramic Oxide
Valves High Grade Stainless Steel
Seals Nitrile With Fabric Reinforcing
Gear End Aluminum Die-Cast

Click the image to enlarge


HORSEPOWER SPECIFICATIONS

RPM GPM 1000 PSI 1100 PSI 1500 PSI 1750 PSI 2000 PSI 2200 PSI
810 2.8 1.9 2.1 2.9 3.4 3.9 4.3
1080 3.8 2.6 2.9 3.9 4.6 5.2 5.8
1450 5.1 3.5 3.9 5.3 6.2 47.0 7.7
1750 6.2 4.3 4.7

Horsepower Requirements

The ratings shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements use the following formulas:

Electric HP = (GPM X PSI)/1450

Gas HP = (GPM X PSI)/1100

*Engine power varies based on horizontal or vertical orientation, as well as by makes and models from each manufacturer.


REPAIR KITS

ITEM# PART# DESCRIPTION Qty.
Plunger Packing Kit – Part #09145
21 07780 O-Ring 3
22 12027 O-Ring 3
23 08358 Grooved Seal 6
24 08346 Pressure  Ring 3
Valve Assembly Kit – Part #09116
31 07853 O-Ring 6
32x 07946A Valve Assembly Complete 6
33 07913 O-Ring 6
Oil Seal Kit – Part #09144
19 08356 Oil Seal 3

Repair Kits Available

The repair kits listed to the right are available for this pump. If you need further information about these repair kits, or have questions about other specific parts for your pump, please contact you local Giant distributor or contact Giant customer service.

PUMP CATEGORIES:
Service & Repair