P219A-3100

A German-made triplex plunger positive displacement pump with reciprocating plungers for direct or belt drive applications.

Features:
Anodized aluminum crankcase with sight glass and vented dipstick; forged, through-hardened, ground and polished crankshaft; bronze connecting rods; hardened stainless steel plunger bases; solid ceramic plungers; nitrile seals (with fabric reinforcing); stainless steel valves and nickel-aluminum-bronze manifold.

Options:
Gearbox and bell housings (to connect to gasoline, diesel, electric or hydraulic drive), couplers (aluminum or Delrin).

  • Exploded View
  • Parts List
  • Giant Limited Warranty
  • Installation Instructions
  • Repair Instructions
  • Trouble Shooting

SPECIFICATIONS

U.S. Metric
1750 RPM
Flow 4.2 GPM 15.9 L/min
Pressure (Continuous) 2000 PSI 140 bar
Maximum Inlet Pressure 145 PSI 10 bar
Plunger Diameter 0.71″ 18 mm
Stroke 0.49″ 12.4 mm
Max. Temperature of Pumped Fluids 160 °F 70 °C
Metric Max. Temperature of Pumped Fluids 86 °F 30 °C
Inlet Ports (2) 1/2″ BSP
Discharge Ports (2) 3/8″ BSP
Shaft Rotation Top of Pulley Towards Fluid End
Crankshaft Diameter 0.94″ 24 mm
Key Width 0.31″ 8 mm
Shaft Mounting Either Side
Weight 13.4 lbs. 6.0 kg
Crankcase Oil Capacity 7.5 fl. oz. 0.22 L
Extended Crankcase Oil Capacity 9.0 fl. oz. 0.27 L
NPSH Required 21.0 Ft.-Head 6.4 mWs
Key Component Material
Manifold Nickel-Aluminum Bronze
Plungers Solid Ceramic Oxide
Valves 316 Stainless Steel
Seals Nitrile With Fabric Reinforcing
Gear End Anodized Aluminum

Click the image to enlarge


HORSEPOWER SPECIFICATIONS

RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI
250 0.6 0.4 0.6 0.8 1.0
500 1.2 0.8 1.2 1.7 2.1
1000 2.4 1.7 2.5 3.3 4.1
1450 3.5 2.4 3.6 4.8 6.0
1750 4.2 2.9 43. 5.8 7.2

Horsepower Requirements

The ratings shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements use the following formulas:

Electric HP = (GPM X PSI)/1450

as HP = (GPM X PSI)/1100

*Engine power varies based on horizontal or vertical orientation, as well as by makes and models from each manufacturer.


REPAIR KITS

ITEM# PART# DESCRIPTION Qty.
Plunger Packing Kit – Part #09602
23 08477 Grooved Seal 3
23A 08087 Grooved Seal Ring 3
23B 06163 Drip Shield 3
24 07904 Pressure Ring 3
Valve Assembly Kit – Part #09714
26A 07946-0100 Valve Assembly 0
33 07913-0001 O-Ring, Viton 0
Oil Seal Kit – Part #09144
19 08356 Oil Seal 3

Repair Kits Available

The repair kits listed to the right are available for this pump. If you need further information about these repair kits, or have questions about other specific parts for your pump, please contact you local Giant distributor or contact Giant customer service.

PUMP CATEGORIES:
Service & Repair

Giant provides service on each pump and accessory that we sell. Many basic repair procedures are covered in the Giant repair manual. For all other questions on service or repair needs please contact your local Giant distributor.